GUDE 8035-1 8-Fold Switched & Metered PDU

GUDE Systems
GUDE 8035-1 8-Fold Switched & Metered PDU

GS-80351

The Expert Power Control 8035-1 ensures operational security and energy efficiency for 19-inch IT and AV installations. With per-port switching, precise metering, self-healing watchdogs, and integrated overvoltage protection, it reduces outages, prevents inrush damage, and enhances reliability while supporting energy-efficient operation.

Variations

Features & Benefits

  • Event and schedule controlled switching
  • Precise current metering of up to 9 electrical units and residual current
  • 2 connectors for plug-and-play sensors
  • Simple and quick mounting due to integrated mounting straps
  • NTP function can be activated
  • Integrated overvoltage protection type 3
  • Each power port can be switched via HTTP(S), SNMP, ModbusTCP or command line interface via Telnet, SSH, MQTT and serial interface
  • Programmable on/off sequences for remote reboots (Remote Reboot)
  • Power ports can be switched when preset sensor thresholds are exceeded
  • Self-healing function thanks to 8-channel watchdog: Each power port can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
  • Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
  • Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second
  • Power consumption metering (kwH) with 2 energy counters: one counter counts consistently, the other counter is resettable
  • Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
  • Metering of differential current type A (mA) and type B (mA) upon request
  • 2 connectors for combined plug-and-play sensors (temperature, humidity and air pressure) to prevent often occurring physical hazards like overheating and increased humidity or air pressure
  • Integrated type 3 overvoltage protection prevents damage to the device and connected loads
  • Long-life High-Inrush Relays prevent welding of relay contacts during inrush current peaks
  • Generation of status messages and alarms (e-mail, syslog, SNMP traps MQTT, SSH, Telnet)
  • Encrypted e-mails (SSL, STARTTLS)
  • Access protection by IP access control
  • Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
  • Password protected access
  • Beeper for audible alarm when sensor limits are exceeded/deceeded
  • IEC-Lock power ports prevent accidental unplugging of power cables (for EPC 8031-2)
  • Easy-to-read LED display for displaying total current, IP address and sensor values
  • Firmware update via Ethernet during operation (no restart required)
  • Simple and flexible configuration via web browser, Windows or Linux program
  • Dynamic assignment of an IP address via DHCP or manual assignment of static IP address